Home > Buy Now > Monitoring & Diagnostic Equipment > Other Monitoring & Diagnostic Equipment > Hanta RAPID - Hanta,Hantaan,Seoul Virus,Hantavirus Detection, Analysis, Test, Diagnostic Kit
 
5 1


ImmuneMed Inc.
 
icon Diagnostic Kit

line

icon Company Profile
icon Selling Leads
icon Index
icon Bulletin Board
icon Guest Book

line



visitors: 2538
 
Contact us
ImmuneMed Inc.
[Korea]
Address:
#2-2, Bldg#3, Chuncheon Biotown, 32, Soyanggang-ro, Chuncheon-si, Gangwon-do 200-957 Korea
Phone:
82-33-2586551
Contact name:
Kang, Ji-Woo , Marketing Representative



ImmuneMed Inc.
 

Hanta RAPID - Hanta,Hantaan,Seoul Virus,Hantavirus Detection, Analysis, Test, Diagnostic Kit

Facebook   Twitter   Delicious   Google   My EC21   Email this page   Report Item Inquire now
Hanta RAPID - Hanta,Hantaan,Seoul Virus,Hantavirus Detection, Analysis, Test, Diagnostic Kit

Click to enlarge image

 Origin

Korea


Hanta RAPID - Diagnostic Kit

Configuration

  • 30 Tests/A Kit
  • 2 Bottles of Diluted Specimens
  • 2 Instructions

Benefits & effects

Furthermore, the Hanta Rapid kit provides rapid interpretation (10 minutes) and can detect IgM and IgG antibody simultaneously which not only helps to be useful for the follow up of the degree of the disease but also the estimation of re-infection and residual antibody as well.

Product Information

"ImmuneMed Hanta Rapid" tests the antibodies against Hantaan and Seoul virus from the patient’s blood using Lateral-Flow Immuno chromatography Assay for the diagnosis of Hemorrhagic Fever with Renal Syndrome (HFRS) by these viruses.

After applying the diluted serum, plasma or blood onto the hole of testing device, lgM antibody of this specimen first reacts with gold conjugated animal anti-human lgM and lgG antibody of this does gold conjugated protein A. Each reactant diffuses on the membrane to recombinant antigen bound to the T (test) line.

If positive, the red line appears on the T line because antigen-antibody complex is forming on T line.

Features

1. Testing Device
One round hole for sample applying on the white plastic cassette and two detection windows for IgM and IgG. The control and test lines are located on the detection windows. Included in the kit - a sample pad, a reddish conjugate pad, a white nitrocellulose membrane and an absorption pad are piled in order.

2. Sample Diluents
Colorless liquid in the semi-transparent plastic bottle.

3. Purpose
Qualitative test for the antibody against Hantaan and Seoul virus from patient's whole blood, serum or plasma.

Materials and Methods

1. Specimen
- Use serum, plasma or whole blood as specimen.
- Collected blood containing anti-coagulant should be used immediately or the blood kept in 2~8°C for 3 days is possible to use.
- Separated serum and plasma could be used until one month if kept in 2~8°C or 1 year if kept frozen.

2. Testing Method
- If each specimen and reagent is kept frozen, place it for 15-30 minutes at room temperature before use.
- After pulling out the testing cassette from the closed pouch, place it on the flat position.
- In case of serum or plasma, 3μℓ is diluted to 300μℓ sample diluents approximately diluted about 100 times. If whole blood, 6μℓ is diluted to 300μℓ sample diluents. After that, drop the 300μℓ of this diluted sample to the injection opening of the specimen by the Micro Pipette. * Or when in case of 3μℓ of serum or plasma, or 6μℓof whole blood, inject so that it will be absorbed to the sample pad of the injection opening by the Micro Pipette, then immediately add the provided 7 drops of sample diluents.
- Wait for 5-10 minutes until the red line appears on the control line. Read and interpret the result from 10 to 20 minutes after applying this diluted sample.

3. Interpretation
- Positive : Red line must appear on each C line of IgM and IgG in the detection windows and one or two red lines should appear on the test line, T in the windows. (Fig 1. a,b,c).
- Negative : Red lines only appear on both control lines of IgM and IgG in the detection windows and no red line should appear on the test line, T. (Fig 1. d).
- If red line does not appear from at least one out of 2 C lines, this result is interpreted as invalid and the test must be done again. (Fig 1. e).

4. Quality Control
- Red lines should appear on both control lines for all IgM and IgG testing.

Precautions

  1. It is used only for in vitro diagnosis.
  2. Due to the deterioration in quality when testing device is exposed to moisture in storage, take out the device from the sealed pouch right before the use and use it within 30 minutes.
  3. Do not touch by hands or have direct contact to the membrane of the detection window of this kit as the test result may be affected.
  4. Avoid moisture, direct sunlight, heat and keep it in room temperature.
  5. Do not use the kit after the expiration date.
  6. If the testing result of test line is positive, it means the antibody is positive against Orientia tsutsugamushi. This kit should be used as the first time diagnosis only. The confirmation test would be necessary if positive and the final diagnosis should be made by a professional doctor after analyzing this test result and other clinical data in conjunction with inquiries.
  7. Precautions of specimen handling and storage
    - Contaminated or heated specimen should not be used for testing.
    - Be careful that serious haemolysis or microbial contaminated specimen may cause inaccurate result.
    - Be careful with handling specimens which may impregnate dangerous sources of unknown viral or bacterial infection. Use disposable gloves when handling the specimen and wash your hands after handling.
    - Solid and liquid waste from experiments should be discarded after high-pressure autoclaving for 15 minutes or more at 121°C.



Inquire now


   
 
 